The 24 Hour Boiler Repairs call centre is open right around the clock. Our team of friendly operators are on hand to take your call and dispatch a highly trained engineer to your door. Our commitment to dealing quickly with all boiler emergencies, regardless of when or where they happen, means we have one of the best response times around. So, rest assured, when you get in contact with 24 Hour Boiler Repairs, your problem will be dealt with at speed by a team of highly skilled professionals. If you have an issue with your heating system, get in touch straight away.
Address
24 Hour Boiler Repairs
86-90 Paul Street
London
EC2A 4NE
Phone
0203 868 6251
Email
info@24hourboilerrepairs.co.uk
Gas Safe registered engineers · 24/7 call handling · London wide
Tell us the fault code and model. We will advise the safest next step.
Common Geminox models we repair include THRi, THRs, Megalisthe, and Geminox condensing boilers, with frequent calls for codes 133, 128, 323, and 119.
We fix Geminox boiler fault codes, no heating, no hot water, lockout, leaking, and low pressure across London.
We also offer boiler servicing and boiler installation across London.
Smell gas? Turn off the gas supply at the meter if it is safe to do so. Open windows. Leave the property. Call the National Gas Emergency Service on 0800 111 999. Do not use switches, and do not use naked flames.
CO alarm sounding? Stop using the boiler. Open doors and windows. Leave the property. Call the National Gas Emergency Service on 0800 111 999. If anyone is drowsy, breathless or has a headache, call 999 as well. Do not re-enter until you are told it is safe.
Boiler leaking heavily? Turn off the boiler at the controls. If safe, turn off the water supply. Call an engineer.
Before calling an engineer, these safe checks may resolve simple issues with your Geminox boiler.
Is gas working at other appliances in your home? If not, check your meter and any prepayment credit.
Pressure should read around 1.0 to 1.5 bar when cold. If below 1 bar, you may need to repressurise using the filling loop.
Is the room thermostat set above current room temperature? Are the batteries working?
Is the heating scheduled to be on? Check the clock is set correctly.
Locate the reset button on your Geminox boiler. Press once and wait. If the fault returns, do not keep resetting. Call an engineer.
In cold weather, the external condensate pipe can freeze. Look for a white plastic pipe exiting through an outside wall. If frozen, pour warm water over it gently.
Every gas repair is carried out by a Gas Safe registered engineer. You are told what needs doing and what it costs before anything starts.
★★★★★4.6/5 on GoogleGeminox boilers do not use the two letter codes most British brands display. They run a Siemens BMU control, so a fault shows as a number — 133, 128, 323 and so on. The codes below are taken from a Geminox installation and maintenance manual. If you have been searching for a Geminox fault letter and finding nothing, this is why.
The boiler tried to light and never proved a flame within its safety time. This is the Geminox equivalent of an ignition lockout and the most common reason one stops. Check gas is on at other appliances, and in freezing weather check the external condensate pipe. Reset once. If 133 returns, call an engineer.
The burner lit normally, then lost the flame while running. Usually the ionisation electrode, gas supply pressure, or flue gas being drawn back into the air intake. Reset once, then call an engineer if it repeats.
The limiter has cut the boiler out because the heat exchanger reached an unsafe temperature. Almost always poor circulation: a failing pump, sludge, closed radiator valves, or a blocked exchanger. Do not keep resetting a limiter lockout. Call an engineer.
Specific to systems with underfloor heating. The limiter protecting the floor circuit has tripped, usually because flow temperature has run too high for the floor build up. Call an engineer.
Flue gas has gone past its permitted limit, which usually points at a scaled or sooted heat exchanger or poor heat transfer into the system. Call an engineer.
System pressure has dropped below the minimum. Top up through the filling loop to between 1.0 and 1.5 bar with the boiler cold. If it falls again within days there is a leak, a weeping pressure relief valve, or a failed expansion vessel. Call an engineer to find it.
The fan is not reaching the speed the boiler needs before it will light, so combustion cannot be proved safe. Call an engineer. Never remove the casing or work on a flue yourself.
An internal fault in the Siemens burner management unit, the boiler's main control. Reset once. If 151 returns, the control needs testing. Call an engineer.
The control's settings are wrong or incomplete for the boiler it is fitted to. Common after a control board swap or a part-finished commissioning. Call an engineer.
The boiler has been deliberately locked out at the control, not stopped by a fault. Often left that way after servicing. Worth calling us before assuming something has broken.
Not a fault. The boiler is telling you a service interval has been reached. It will keep running, but book the service. See boiler servicing London.
On systems with a hot water cylinder, the anti legionella cycle did not get the water hot enough. Worth attending to rather than ignoring. Call an engineer.
A sensor has been wired to a configurable input that has not been assigned a job, or the sensor has failed. A commissioning fault rather than a broken boiler. Call an engineer.
An add on module, typically controlling a mixed circuit or a cylinder, has a fault or has lost communication with the boiler. Call an engineer.
An external contact wired into the control has signalled a fault. What it means depends on what was wired to it at installation, so it needs someone who can read the commissioning settings. Call an engineer.
If the display is blank or the boiler simply is not firing with no number shown, check the room thermostat, the programmer and its batteries, and the fused spur. If those are all right, call us.
Note: Geminox is a European brand and its controls have changed across the THR, THRi, THRs and Merite ranges, so the same number does not always mean the same thing on every unit. The codes above come from a Geminox installation and maintenance manual and cover the faults we are called to most. If your display shows a number that is not listed, do not match it against a code list for another make simply because the number looks familiar. Call us with the number and the model from the data badge and we will tell you what it means before anyone attends.
Call with your model and the code on the display. We will tell you what is likely involved before anyone attends.
If you are seeing a lockout, loss of hot water, or your Geminox boiler keeps resetting, tell us the fault code and model and we will confirm the safest next step.
Code 133 is the one you are most likely to see on a Geminox. The boiler attempted to light and no flame was proved. Common causes include a gas supply problem, a worn or sooted ionisation electrode, or a blocked condensate pipe in winter. Check gas is on elsewhere in the home. Reset once. If the lockout returns, stop and call an engineer.
If your Geminox shows 323, system pressure has dropped below the minimum operating level. Top up via the filling loop to around 1.0 to 1.5 bar when cold. If pressure drops again within days, there may be a leak in the system or a failing expansion vessel. Call an engineer to find the cause.
If your Geminox shows 119, the heat exchanger limiter has tripped and the boiler has locked out for safety. This can indicate a circulation problem, pump failure, or a blocked heat exchanger. Do not keep resetting. Call an engineer to check the system.
On Geminox combi boilers, you may get heating but no hot water, or the reverse. This often points to a diverter valve issue. The diverter valve directs hot water between taps and radiators. When it wears or sticks, hot water delivery becomes unreliable. Call an engineer for diagnosis.
Geminox is a European manufacturer with a range of condensing boilers. Here is what we commonly see.
The control proves the flame through an ionisation electrode, which is why codes 133 and 128 are the two we see most. When the electrode wears, sooths over or drifts out of position, the boiler cannot prove a flame and locks out. Condensate blockages in winter contribute to repeat lockouts too.
Code 323 usually points to a failing expansion vessel or a weeping pressure relief valve. The expansion vessel absorbs pressure changes as water heats and cools. If the diaphragm fails or the air charge is lost, pressure drops can occur.
Codes 119 and 130 both point at heat not getting away from the boiler quickly enough. This may be caused by a failing pump, sludge buildup, or closed radiator valves. A powerflush may help restore flow.
Geminox runs a configurable Siemens control, which is a strength when it is set up properly and a nuisance when it is not. Codes 152 and the 330 series are settings faults rather than broken parts, and they often show up after a board change or an unfinished commissioning.
The diverter valve directs hot water between your taps and radiators. When it wears or sticks, you may get heating but no hot water, or the reverse.
We repair Geminox combi, system, and regular boilers in London, including:
We repair every Geminox model
Combi, system and regular boilers, current ranges and older units
Geminox parts can be more specialist than mainstream UK brands. We check availability before attending and advise honestly if repair is not viable or cost effective.
We help you decide based on age, reliability, and parts availability.
Our engineers give honest assessments. We focus on safety and reliability, not pushing unnecessary replacements.
Annual servicing reduces breakdown risk and keeps your Geminox boiler running efficiently. See Boiler servicing London.
We provide boiler repairs and gas safety certification for landlords across London. See Landlord gas safety certificate (CP12).
London wide coverage for Geminox boiler repairs. Book an engineer or view our London areas we cover.
Have your postcode and fault code ready and we will confirm the quickest appointment slot.
Worcester Boiler Repairs
Vaillant Boiler Repairs
Ideal Boiler Repairs
Baxi Boiler Repairs
Glow-worm Boiler Repairs
Viessmann Boiler Repairs
Potterton Boiler Repairs
Main Boiler Repairs
Vokera Boiler Repairs
Alpha Boiler Repairs
Ferroli Boiler Repairs
Ariston Boiler Repairs
Worcester • Vaillant • Ideal • Baxi • Glow-worm • Viessmann • Potterton • Vokera • Alpha • Ferroli
View all brands ›
We offer same day attendance where slots are available. For no heating or hot water, we prioritise urgent breakdowns. Call our 24/7 line and we will advise availability.
Geminox uses a Siemens burner management control, which reports faults as numbers rather than the two letter codes most British brands display. A Geminox showing 133 is telling you it could not prove a flame. There is nothing wrong with the display.
Geminox parts can be more specialist than mainstream UK brands. We check availability and source parts as quickly as possible. For common faults, we often have compatible components available.
Try one reset. If the fault returns after resetting, stop and call an engineer. Do not keep resetting, especially for 119 and 110 where a safety limiter has tripped.
Verified Google reviews. 4.6 out of 5.
Excellent from start to finish. The Engineer was helpful on the phone diagnosing the issue, and was able to start and finish the work in good time, and made every effort to do the best job possible. All working well, and was able to get a long guarantee.
GeorgeGoogle reviewGreat guy on time true professional resolve the issue same day
David BrazierGoogle reviewGood value for money & was able to sort out my boiler quickly by ordering next day delivery for broken parts. Friendly, punctual service and laid out all the costs beforehand which was helpful. Would recommend.
Emma CourtneyGoogle reviewFor safe next steps, call now.
Call 0203 868 6251 Gas Safe registered · 24/7 call handling · Quote before work
Good value for money & was able to sort out my boiler quickly by ordering next day delivery for broken parts. Friendly, punctual service and laid out all the costs beforehand which was helpful. Would recommend.
Emma CourtneyGoogle reviewReally impressed with the boiler repair service. Clear communication from the start and no surprises with pricing. The engineer was friendly, knowledgeable and got everything sorted efficiently.
Nishanth ThachemaGoogle reviewUsed this company after being recommended and I’m glad I did. The engineer was punctual, honest about costs and carried out the work to a very high standard. Felt like a trustworthy service.
Siva YelakarajulaGoogle reviewLines are open 24 hours. Call us, or leave four details and we will call you back.
0203 868 6251 24 Hour Boiler Repairs