The 24 Hour Boiler Repairs call centre is open right around the clock. Our team of friendly operators are on hand to take your call and dispatch a highly trained engineer to your door. Our commitment to dealing quickly with all boiler emergencies, regardless of when or where they happen, means we have one of the best response times around. So, rest assured, when you get in contact with 24 Hour Boiler Repairs, your problem will be dealt with at speed by a team of highly skilled professionals. If you have an issue with your heating system, get in touch straight away.
Address
24 Hour Boiler Repairs
86-90 Paul Street
London
EC2A 4NE
Phone
0203 868 6251
Email
info@24hourboilerrepairs.co.uk
Gas Safe registered engineers · 24/7 call handling · London wide
Tell us the fault code and model. We will advise the safest next step.
Common Worcester models we repair include Greenstar, Greenstar i, Greenstar CDi, and Greenstar Si, with frequent calls for codes EA, E9, CE, and C6.
We fix Worcester Bosch boiler fault codes, no heating, no hot water, lockout, leaking, and low pressure across London.
We also offer boiler servicing and boiler installation across London.
Smell gas? Turn off the gas supply at the meter if it is safe to do so. Open windows. Leave the property. Call the National Gas Emergency Service on 0800 111 999. Do not use switches, and do not use naked flames.
CO alarm sounding? Stop using the boiler. Open doors and windows. Leave the property. Call the National Gas Emergency Service on 0800 111 999. If anyone is drowsy, breathless or has a headache, call 999 as well. Do not re-enter until you are told it is safe.
Boiler leaking heavily? Turn off the boiler at the controls. If safe, turn off the water supply. Call an engineer.
Before calling an engineer, these safe checks may resolve simple issues with your Worcester Bosch boiler.
Is gas working at other appliances in your home? If not, check your meter and any prepayment credit.
Pressure should read around 1.0 to 1.5 bar when cold. If below 1 bar, you may need to repressurise using the filling loop.
Is the room thermostat set above current room temperature? Are the batteries working?
Is the heating scheduled to be on? Check the clock is set correctly.
Locate the reset button on your Worcester boiler. Press once and wait. If the fault returns, do not keep resetting. Call an engineer.
In cold weather, the external condensate pipe can freeze. Look for a white plastic pipe exiting through an outside wall. If frozen, pour warm water over it gently.
Every gas repair is carried out by a Gas Safe registered engineer. You are told what needs doing and what it costs before anything starts.
★★★★★4.6/5 on GoogleThe codes below are taken from Worcester Bosch's own published fault tables. Greenstar boilers use two families: older and current models show a two character code such as EA or E9, while Greenstar 4000, 8000 and boilers running an EMS control show a longer numeric code such as 227 or 2971. Both are listed.
The most common Worcester code. The boiler attempted to light but no flame was proved. Worcester's own manual says to check whether the gas is on elsewhere in the house, whether the condensate pipe is frozen, and whether the flue outlet is blocked, but only where it is safe to do so. Reset once. If EA returns, call an engineer.
The numeric equivalent of EA on EMS controlled models. Same checks: gas on elsewhere, condensate not frozen. Reset once only, then call an engineer.
The boiler still sees a flame signal after the gas valve has closed. Do not reset repeatedly and do not ignore it. Turn the boiler off at the controls and call an engineer.
A flame signal is present when the burner should be shut down. Like FA, this is a gas safety fault. Switch the boiler off and call an engineer.
Worcester's manual wording is that the safety temperature limiter in the central heating flow has tripped. The boiler has reached an unsafe temperature and locked out deliberately. Usually poor circulation, a failing pump, sludge, or a blocked heat exchanger. Do not keep resetting a limiter lockout. Call an engineer.
The numeric equivalent of E9. Same cause and the same rule: do not keep resetting. Call an engineer.
The flow temperature has climbed past its permitted level, often for the same reasons as E9. Call an engineer.
The flow sensor is reading incorrectly or has failed. Reset once. If it returns, call an engineer to test the sensor and its wiring.
The return temperature sensor has a fault. The boiler cannot judge the temperature difference across the system safely. Call an engineer.
The domestic hot water sensor has failed. You may get heating but unreliable hot water. Call an engineer.
Also shown as 1017 or 2971 on newer models. Top the system up through the filling loop to between 1.0 and 1.5 bar with the boiler cold. If it drops again within days there is a leak, a weeping pressure relief valve, or a failed expansion vessel. Call an engineer to find it.
The pump is seized, airlocked, or the system has lost water. Check the pressure gauge first. If pressure is correct and A1 stays, call an engineer.
Where a condensate pump is fitted, it has failed and the boiler has stopped to avoid an overflow. Call an engineer.
The fan is not running at the speed the boiler expects, so combustion cannot be proved safe. Call an engineer. Never remove the casing or work on a flue yourself.
The fan has not started, so the boiler will not attempt ignition. Call an engineer.
The fan stopped while the burner was running. The boiler locks out immediately. Call an engineer.
The most harmless code on the list. The reset was pressed when there was no fault. Press reset once more and the boiler should return to normal.
The code plug that tells the control board which boiler it is fitted to is missing, loose or unreadable. Call an engineer.
An internal control fault. Reset once. If F0 returns, the control board or gas valve needs testing. Call an engineer.
If the display is blank or the boiler simply is not firing with no code shown, check the thermostat, the programmer and its batteries, and the fused spur. If all of those are right, call us.
Note: Worcester fault codes vary between the Greenstar i, Si, CDi, ri, 4000 and 8000 ranges, and between older and EMS controls. If your code is not listed above, call us with the exact code and the model from the data badge and we will tell you what it means before anyone attends.
Call with your model and the code on the display. We will tell you what is likely involved before anyone attends.
If you are seeing a lockout, loss of hot water, or your Worcester boiler keeps resetting, tell us the fault code and model and we will confirm the safest next step.
EA is the most common Worcester fault code. The boiler is trying to ignite but cannot establish a stable flame. Common causes include gas supply issues, a faulty ignition electrode, or a blocked condensate pipe in winter. Check whether your gas hob works. In freezing weather check the condensate pipe. Reset once only. If EA returns, call an engineer.
If your Worcester shows a low pressure warning, system pressure has dropped below the minimum threshold. Top up via the filling loop to around 1.0 to 1.5 bar when cold. If pressure drops again within days, there may be a leak in the system or a failing expansion vessel. Call an engineer to find the cause.
If your Worcester shows E9, the boiler has overheated and locked out for safety. This can indicate a circulation problem, pump failure, or blocked heat exchanger. Do not keep resetting. Call an engineer to check the system.
On Worcester combi boilers, you may get heating but no hot water, or the reverse. This often points to a diverter valve issue. The diverter valve directs hot water between taps and radiators. When it wears or sticks, hot water delivery becomes unreliable. Call an engineer for diagnosis.
Worcester Bosch is one of the most popular boiler brands in the UK, known for reliability. Here is what we commonly see.
Ignition faults (EA) can occur when the ignition electrode wears or becomes coated with carbon. Condensate blockages in winter can also contribute to repeated lockouts.
Low pressure faults often point to a failing expansion vessel or a weeping pressure relief valve. The expansion vessel absorbs pressure changes as water heats and cools. If the diaphragm fails or the air charge is lost, pressure drops can occur.
E9 overheat faults can indicate poor circulation through the system. This may be caused by a failing pump, sludge buildup, or closed radiator valves. A powerflush may help restore flow.
Fan faults prevent safe combustion and flue gas extraction. The boiler will lock out for safety. Causes include fan motor failure, wiring faults, or flue blockages.
The diverter valve directs hot water between your taps and radiators. When it wears or sticks, you may get heating but no hot water, or the reverse.
We repair Worcester Bosch combi, system, and regular boilers in London, including:
We repair every Worcester model
Combi, system and regular boilers, current ranges and older units
Worcester Bosch parts are widely available through their UK network. We check availability before attending and advise honestly if repair is not viable or cost effective.
We help you decide based on age, reliability, and parts availability.
Our engineers give honest assessments. We focus on safety and reliability, not pushing unnecessary replacements.
Annual servicing reduces breakdown risk and keeps your Worcester boiler running efficiently. See Boiler servicing London.
We provide boiler repairs and gas safety certification for landlords across London. See Landlord gas safety certificate (CP12).
London wide coverage for Worcester Bosch boiler repairs. Book an engineer or view our London areas we cover.
Have your postcode and fault code ready and we will confirm the quickest appointment slot.
Vaillant Boiler Repairs
Ideal Boiler Repairs
Baxi Boiler Repairs
Glow-worm Boiler Repairs
Viessmann Boiler Repairs
Potterton Boiler Repairs
Main Boiler Repairs
Vokera Boiler Repairs
Alpha Boiler Repairs
Ferroli Boiler Repairs
Ariston Boiler Repairs
Ravenheat Boiler Repairs
Vaillant • Ideal • Baxi • Glow-worm • Viessmann • Potterton • Main • Vokera • Alpha • Ferroli
View all brands ›
We offer same day attendance where slots are available. For no heating or hot water, we prioritise urgent breakdowns. Call our 24/7 line and we will advise availability.
We stock common Worcester parts including diverter valves, ignition electrodes, pressure sensors, fans, and PCBs. Worcester parts are widely available.
Try one reset. If the fault returns after resetting, stop and call an engineer. Do not keep resetting, especially for E9 or 224 overheat faults, or for FA and F7 where a flame is detected when it should not be.
Costs vary depending on the fault and parts required. We diagnose first and quote before any repair work begins.
Verified Google reviews. 4.6 out of 5.
Resourceful and helpful with the issue we had with our boiler
Katarina JezovnikGoogle reviewGood value for money & was able to sort out my boiler quickly by ordering next day delivery for broken parts. Friendly, punctual service and laid out all the costs beforehand which was helpful. Would recommend.
Emma CourtneyGoogle reviewGreat guy on time true professional resolve the issue same day
David BrazierGoogle reviewFor safe next steps, call now.
Call 0203 868 6251 Gas Safe registered · 24/7 call handling · Quote before work
Booked them in for a power flush after ongoing heating issues. The engineer was very thorough and explained what was being done at each stage. We noticed a huge difference in how quickly the radiators now heat up.
S ThanuGoogle reviewGood value for money & was able to sort out my boiler quickly by ordering next day delivery for broken parts. Friendly, punctual service and laid out all the costs beforehand which was helpful. Would recommend.
Emma CourtneyGoogle reviewUsed this company after being recommended and I’m glad I did. The engineer was punctual, honest about costs and carried out the work to a very high standard. Felt like a trustworthy service.
Siva YelakarajulaGoogle reviewLines are open 24 hours. Call us, or leave four details and we will call you back.
0203 868 6251 24 Hour Boiler Repairs