The 24 Hour Boiler Repairs call centre is open right around the clock. Our team of friendly operators are on hand to take your call and dispatch a highly trained engineer to your door. Our commitment to dealing quickly with all boiler emergencies, regardless of when or where they happen, means we have one of the best response times around. So, rest assured, when you get in contact with 24 Hour Boiler Repairs, your problem will be dealt with at speed by a team of highly skilled professionals. If you have an issue with your heating system, get in touch straight away.
Address
24 Hour Boiler Repairs
86-90 Paul Street
London
EC2A 4NE
Phone
0203 868 6251
Email
info@24hourboilerrepairs.co.uk
Gas Safe registered engineers • 24/7 call handling • London wide
Tell us the fault code and model. We will advise the safest next step.
Common Worcester models we repair include Greenstar, Greenstar i, Greenstar CDi, and Greenstar Si, with frequent calls for codes EA, E9, low pressure, and fan faults.
We fix Worcester Bosch boiler fault codes, no heating, no hot water, lockout, leaking, and low pressure across London.
We also offer boiler servicing and boiler installation across London.
Smell gas? Turn off the gas supply at the meter if it is safe to do so. Open windows. Leave the property. Call the National Gas Emergency Service on 0800 111 999. Do not use switches, and do not use naked flames.
CO alarm sounding? Open windows immediately. Leave the property. Call 999. Do not re-enter until cleared by emergency services.
Boiler leaking heavily? Turn off the boiler at the controls. If safe, turn off the water supply. Call an engineer.
Before calling an engineer, these safe checks may resolve simple issues with your Worcester Bosch boiler.
Check the gas supply
Is gas working at other appliances in your home? If not, check your meter and any prepayment credit.
Check the pressure gauge
Pressure should read around 1.0 to 1.5 bar when cold. If below 1 bar, you may need to repressurise using the filling loop.
Check the thermostat
Is the room thermostat set above current room temperature? Are the batteries working?
Check the timer or programmer
Is the heating scheduled to be on? Check the clock is set correctly.
Try a single reset
Locate the reset button on your Worcester boiler. Press once and wait. If the fault returns, do not keep resetting. Call an engineer.
Check the condensate pipe
In cold weather, the external condensate pipe can freeze. Look for a white plastic pipe exiting through an outside wall. If frozen, pour warm water over it gently.
Common Worcester fault codes and what to do
| Code | Meaning | What To Do |
|---|---|---|
| EA | No flame / ignition failure | Check gas supply and other appliances. Check condensate in freezing weather. If it returns, call an engineer. |
| E9 | Overheat / safety trip | Do not keep resetting. Call an engineer to check circulation and safety controls. |
| Low pressure | System pressure too low | Top up to 1.0 to 1.5 bar. If it drops again, call an engineer. |
| Flue / airflow | Airflow safety issue | Call an engineer. Do not attempt DIY on flues. |
| Fan fault | Fan not proving correctly | Call an engineer. |
| Heat demand issue | Controls not calling for heat | Check thermostat, programmer and batteries. If unsure, call us. |
If you are seeing a lockout, loss of hot water, or your Worcester boiler keeps resetting, tell us the fault code and model and we will confirm the safest next step.
EA is the most common Worcester fault code. The boiler is trying to ignite but cannot establish a stable flame. Common causes include gas supply issues, a faulty ignition electrode, or a blocked condensate pipe in winter. Check whether your gas hob works. In freezing weather check the condensate pipe. Reset once only. If EA returns, call an engineer.
If your Worcester shows a low pressure warning, system pressure has dropped below the minimum threshold. Top up via the filling loop to around 1.0 to 1.5 bar when cold. If pressure drops again within days, there may be a leak in the system or a failing expansion vessel. Call an engineer to find the cause.
If your Worcester shows E9, the boiler has overheated and locked out for safety. This can indicate a circulation problem, pump failure, or blocked heat exchanger. Do not keep resetting. Call an engineer to check the system.
On Worcester combi boilers, you may get heating but no hot water, or the reverse. This often points to a diverter valve issue. The diverter valve directs hot water between taps and radiators. When it wears or sticks, hot water delivery becomes unreliable. Call an engineer for diagnosis.
Worcester Bosch is one of the most popular boiler brands in the UK, known for reliability. Here is what we commonly see.
Ignition faults (EA) can occur when the ignition electrode wears or becomes coated with carbon. Condensate blockages in winter can also contribute to repeated lockouts.
Low pressure faults often point to a failing expansion vessel or a weeping pressure relief valve. The expansion vessel absorbs pressure changes as water heats and cools. If the diaphragm fails or the air charge is lost, pressure drops can occur.
E9 overheat faults can indicate poor circulation through the system. This may be caused by a failing pump, sludge buildup, or closed radiator valves. A powerflush may help restore flow.
Fan faults prevent safe combustion and flue gas extraction. The boiler will lock out for safety. Causes include fan motor failure, wiring faults, or flue blockages.
The diverter valve directs hot water between your taps and radiators. When it wears or sticks, you may get heating but no hot water, or the reverse.
We repair Worcester Bosch combi, system, and regular boilers in London, including:
Greenstar i range: Greenstar 25i, Greenstar 30i, Greenstar 35i
Greenstar Si range: Greenstar 25Si, Greenstar 30Si
Greenstar CDi range: Greenstar 27CDi, Greenstar 30CDi, Greenstar 37CDi, Greenstar 42CDi
Greenstar ri range: Greenstar 27ri, Greenstar 30ri
Greenstar 8000 range: 8000 Life, 8000 Style
Other models: Greenstar Highflow, Greenstar FS, and older Worcester units
Worcester Bosch parts are widely available through their UK network. We check availability before attending and advise honestly if repair is not viable or cost effective.
We help you decide based on age, reliability, and parts availability.
Our engineers give honest assessments. We focus on safety and reliability, not pushing unnecessary replacements.
Annual servicing reduces breakdown risk and keeps your Worcester boiler running efficiently. See Boiler servicing London.
We provide boiler repairs and gas safety certification for landlords across London. See Landlord gas safety certificate (CP12).
London wide coverage for Worcester Bosch boiler repairs. Book an engineer or view our London areas we cover.
Have your postcode and fault code ready and we will confirm the quickest appointment slot.
Vaillant • Ideal • Baxi • Glow-worm • Viessmann • Potterton • Main • Vokera • Alpha • Ferroli
We offer same day attendance where slots are available. For no heating or hot water, we prioritise urgent breakdowns. Call our 24/7 line and we will advise availability.
We stock common Worcester parts including diverter valves, ignition electrodes, pressure sensors, fans, and PCBs. Worcester parts are widely available.
Try one reset. If the fault returns after resetting, stop and call an engineer. Do not keep resetting, especially for E9 overheat faults.
Costs vary depending on the fault and parts required. We diagnose first and quote before any repair work begins.
For safe next steps, call now.
Call 0203 868 6251 | Book an Engineer
Gas Safe registered • 24/7 call handling • Quote before work
Not only did they fix our boiler, they handled the whole thing with such speed and professionalism.
Paul Dunne - Leytonstone, London
24 Hour Boiler Repairs installed our system, serviced it and, if we ever have an emergency, it’s them we will call. Trustworthy, friendly and professional.
S. Joyce - Bank, London.
We called 24 Hour Boiler Repairs at 11pm expecting to be informed that an engineer wouldn't be available until the morning but we had an engineer at our door by 12:30am. Great Service.
T. Green - Hackney, London