The 24 Hour Boiler Repairs call centre is open right around the clock. Our team of friendly operators are on hand to take your call and dispatch a highly trained engineer to your door. Our commitment to dealing quickly with all boiler emergencies, regardless of when or where they happen, means we have one of the best response times around. So, rest assured, when you get in contact with 24 Hour Boiler Repairs, your problem will be dealt with at speed by a team of highly skilled professionals. If you have an issue with your heating system, get in touch straight away.
Address
24 Hour Boiler Repairs
86-90 Paul Street
London
EC2A 4NE
Phone
0203 868 6251
Email
info@24hourboilerrepairs.co.uk
Gas Safe registered engineers · 24/7 call handling · London wide
Tell us the fault code and model. We will advise the safest next step.
Common Vokera models we repair include Mynute, Compact, Easi-Flo, and Linea, with frequent calls for codes A01, A04, A06, and A08.
We fix Vokera boiler fault codes, no heating, no hot water, lockout, leaking, and low pressure across London.
We also offer boiler servicing and boiler installation across London.
Smell gas? Turn off the gas supply at the meter if it is safe to do so. Open windows. Leave the property. Call the National Gas Emergency Service on 0800 111 999. Do not use switches, and do not use naked flames.
CO alarm sounding? Stop using the boiler. Open doors and windows. Leave the property. Call the National Gas Emergency Service on 0800 111 999. If anyone is drowsy, breathless or has a headache, call 999 as well. Do not re-enter until you are told it is safe.
Boiler leaking heavily? Turn off the boiler at the controls. If safe, turn off the water supply. Call an engineer.
Before calling an engineer, these safe checks may resolve simple issues with your Vokera boiler.
Is gas working at other appliances in your home? If not, check your meter and any prepayment credit.
Pressure should read around 1.0 to 1.5 bar when cold. If below 1 bar, you may need to repressurise using the filling loop.
Is the room thermostat set above current room temperature? Are the batteries working?
Is the heating scheduled to be on? Check the clock is set correctly.
Locate the reset button on your Vokera boiler. Press once and wait. If the fault returns, do not keep resetting. Call an engineer.
In cold weather, the external condensate pipe can freeze. Look for a white plastic pipe exiting through an outside wall. If frozen, pour warm water over it gently.
Every gas repair is carried out by a Gas Safe registered engineer. You are told what needs doing and what it costs before anything starts.
★★★★★4.6/5 on GoogleCommon Vokera fault codes and what to do
Check gas supply and other appliances. Check condensate pipe in freezing weather. If still locked out, call an engineer.
Check gas supply and condensate pipe. If still locked out, call an engineer.
Top up pressure using filling loop (see below). If it drops again within days, call an engineer.
Reset once. If it happens again, call an engineer.
Check radiators are getting hot. If circulation seems poor, call an engineer.
Note: Vokera uses A codes on most models. If unsure, call us and we will help you identify your specific code.
Call with your model and the code on the display. We will tell you what is likely involved before anyone attends.
If you are seeing a lockout, loss of hot water, or your Vokera boiler keeps resetting, tell us the fault code and model and we will confirm the safest next step.
A01 and A04 are the most common Vokera fault codes. The boiler tries to ignite but no flame is established, or locks out after multiple failed attempts. Common causes include gas supply issues, a faulty ignition electrode, or a blocked condensate pipe in winter. Check gas is on elsewhere in the home. Try one reset. If the lockout returns, stop and call an engineer.
If your Vokera shows A06, system pressure has dropped below the minimum threshold. Top up via the filling loop to around 1.0 to 1.5 bar when cold. If pressure drops again within days, there may be a leak in the system or a failing expansion vessel. Call an engineer to find the cause.
A12 indicates the boiler has detected poor or no flow through the system. Check your radiators are getting hot. If circulation seems poor, there may be a pump issue, airlock, or sludge buildup. Call an engineer to diagnose and repair.
On Vokera combi boilers, you may get heating but no hot water, or the reverse. This often points to a diverter valve issue. The diverter valve directs hot water between taps and radiators. When it wears or sticks, hot water delivery becomes unreliable. Call an engineer for diagnosis.
Vokera is part of the Riello Group and manufactures a range of boilers in the UK. Here is what we commonly see.
Ignition faults (A01, A04, A08) can occur when the ignition electrode wears or becomes coated with carbon. Condensate blockages in winter can also contribute to repeated lockouts.
Low pressure faults often point to a failing expansion vessel or a weeping pressure relief valve. The expansion vessel absorbs pressure changes as water heats and cools. If the diaphragm fails or the air charge is lost, pressure drops can occur.
A12 can indicate poor circulation through the system. This may be caused by a failing pump, sludge buildup, or closed radiator valves. A powerflush may help restore flow.
Fan faults prevent safe combustion and flue gas extraction. The boiler will lock out for safety. Causes include fan motor failure, wiring faults, or flue sensor issues.
The diverter valve directs hot water between your taps and radiators. When it wears or sticks, you may get heating but no hot water, or the reverse.
We repair Vokera combi, system, and regular boilers in London, including:
We repair every Vokera model
Combi, system and regular boilers, current ranges and older units
Vokera parts are generally available through their UK network. We check availability before attending and advise honestly if repair is not viable or cost effective.
We help you decide based on age, reliability, and parts availability.
Our engineers give honest assessments. We focus on safety and reliability, not pushing unnecessary replacements.
Annual servicing reduces breakdown risk and keeps your Vokera boiler running efficiently. See Boiler servicing London.
We provide boiler repairs and gas safety certification for landlords across London. See Landlord gas safety certificate (CP12).
London wide coverage for Vokera boiler repairs. Book an engineer or view our London areas we cover.
Have your postcode and fault code ready and we will confirm the quickest appointment slot.
Worcester Boiler Repairs
Vaillant Boiler Repairs
Ideal Boiler Repairs
Baxi Boiler Repairs
Glow-worm Boiler Repairs
Viessmann Boiler Repairs
Potterton Boiler Repairs
Main Boiler Repairs
Alpha Boiler Repairs
Ferroli Boiler Repairs
Ariston Boiler Repairs
Ravenheat Boiler Repairs
Worcester • Vaillant • Ideal • Baxi • Glow-worm • Viessmann • Potterton • Main • Alpha • Ferroli
View all brands ›
We offer same day attendance where slots are available. For no heating or hot water, we prioritise urgent breakdowns. Call our 24/7 line and we will advise availability.
We stock common Vokera parts including diverter valves, ignition electrodes, pressure sensors, fans, and PCBs. Parts are available through the Vokera network.
Try one reset. If the fault returns after resetting, stop and call an engineer. Do not keep resetting.
Costs vary depending on the fault and parts required. We diagnose first and quote before any repair work begins.
Verified Google reviews. 4.6 out of 5.
Resourceful and helpful with the issue we had with our boiler
Katarina JezovnikGoogle reviewFix the boiler same day great job life saver
B M Sidratul MuntahaGoogle reviewGreat service- fast, professional, clear and reasonable. Thanks Steve!
Isolde MurphyGoogle reviewFor safe next steps, call now.
Call 0203 868 6251 Gas Safe registered · 24/7 call handling · Quote before work
Used this company after being recommended and I’m glad I did. The engineer was punctual, honest about costs and carried out the work to a very high standard. Felt like a trustworthy service.
Siva YelakarajulaGoogle reviewBooked them in for a power flush after ongoing heating issues. The engineer was very thorough and explained what was being done at each stage. We noticed a huge difference in how quickly the radiators now heat up.
S ThanuGoogle reviewReally impressed with the boiler repair service. Clear communication from the start and no surprises with pricing. The engineer was friendly, knowledgeable and got everything sorted efficiently.
Nishanth ThachemaGoogle review