Call us 24 Hours a day Show Navigation
Contact Us

The 24 Hour Boiler Repairs call centre is open right around the clock. Our team of friendly operators are on hand to take your call and dispatch a highly trained engineer to your door. Our commitment to dealing quickly with all boiler emergencies, regardless of when or where they happen, means we have one of the best response times around. So, rest assured, when you get in contact with 24 Hour Boiler Repairs, your problem will be dealt with at speed by a team of highly skilled professionals. If you have an issue with your heating system, get in touch straight away.


Address
24 Hour Boiler Repairs
86-90 Paul Street
London
EC2A 4NE

Request a callback

Need a Gas Safe engineer in London ASAP? Call us 24 Hours a day!

Geminox

Geminox Boiler Repairs London

Gas Safe registered engineers · 24/7 call handling · London wide

Tell us the fault code and model. We will advise the safest next step.

  • Experienced Geminox Boiler Repairs specialists
  • Available 24 hours a day, 7 days a week
  • Insurance approved
  • All parts guaranteed for a year
  • Fully Gas Safe trained engineers

Lines open now

0203 868 6251

Have your Geminox model and fault code ready.

★★★★★4.6/5 on Google

Common Geminox models we repair include THRi, THRs, Megalisthe, and Geminox condensing boilers, with frequent calls for codes 133, 128, 323, and 119.

We fix Geminox boiler fault codes, no heating, no hot water, lockout, leaking, and low pressure across London.

We also offer boiler servicing and boiler installation across London.

Safety First

Smell gas? Turn off the gas supply at the meter if it is safe to do so. Open windows. Leave the property. Call the National Gas Emergency Service on 0800 111 999. Do not use switches, and do not use naked flames.

CO alarm sounding? Stop using the boiler. Open doors and windows. Leave the property. Call the National Gas Emergency Service on 0800 111 999. If anyone is drowsy, breathless or has a headache, call 999 as well. Do not re-enter until you are told it is safe.

Boiler leaking heavily? Turn off the boiler at the controls. If safe, turn off the water supply. Call an engineer.

Quick Checks Before You Call

Before calling an engineer, these safe checks may resolve simple issues with your Geminox boiler.

Check the gas supply

Is gas working at other appliances in your home? If not, check your meter and any prepayment credit.

Check the pressure gauge

Pressure should read around 1.0 to 1.5 bar when cold. If below 1 bar, you may need to repressurise using the filling loop.

Check the thermostat

Is the room thermostat set above current room temperature? Are the batteries working?

Check the timer or programmer

Is the heating scheduled to be on? Check the clock is set correctly.

Try a single reset

Locate the reset button on your Geminox boiler. Press once and wait. If the fault returns, do not keep resetting. Call an engineer.

Check the condensate pipe

In cold weather, the external condensate pipe can freeze. Look for a white plastic pipe exiting through an outside wall. If frozen, pour warm water over it gently.

Gas Safe registered boiler engineers

Fully Gas Safe trained engineers

Every gas repair is carried out by a Gas Safe registered engineer. You are told what needs doing and what it costs before anything starts.

★★★★★4.6/5 on Google

Geminox Fault Codes

Geminox boilers do not use the two letter codes most British brands display. They run a Siemens BMU control, so a fault shows as a number — 133, 128, 323 and so on. The codes below are taken from a Geminox installation and maintenance manual. If you have been searching for a Geminox fault letter and finding nothing, this is why.

Code/What It Means/What To Do

Flame and ignition

133 Flame not detected

The boiler tried to light and never proved a flame within its safety time. This is the Geminox equivalent of an ignition lockout and the most common reason one stops. Check gas is on at other appliances, and in freezing weather check the external condensate pipe. Reset once. If 133 returns, call an engineer.

128 Flame fault in operation

The burner lit normally, then lost the flame while running. Usually the ionisation electrode, gas supply pressure, or flue gas being drawn back into the air intake. Reset once, then call an engineer if it repeats.

Overheating and flue gas

119 Heat exchanger temperature limiter has responded

The limiter has cut the boiler out because the heat exchanger reached an unsafe temperature. Almost always poor circulation: a failing pump, sludge, closed radiator valves, or a blocked exchanger. Do not keep resetting a limiter lockout. Call an engineer.

110 Underfloor temperature limiter has responded

Specific to systems with underfloor heating. The limiter protecting the floor circuit has tripped, usually because flow temperature has run too high for the floor build up. Call an engineer.

130 Maximum flue gas temperature exceeded

Flue gas has gone past its permitted limit, which usually points at a scaled or sooted heat exchanger or poor heat transfer into the system. Call an engineer.

Water pressure and fan

323 Water pressure too low

System pressure has dropped below the minimum. Top up through the filling loop to between 1.0 and 1.5 bar with the boiler cold. If it falls again within days there is a leak, a weeping pressure relief valve, or a failed expansion vessel. Call an engineer to find it.

160 Fan speed threshold not reached

The fan is not reaching the speed the boiler needs before it will light, so combustion cannot be proved safe. Call an engineer. Never remove the casing or work on a flue yourself.

Control and configuration

151 BMU fault

An internal fault in the Siemens burner management unit, the boiler's main control. Reset once. If 151 returns, the control needs testing. Call an engineer.

152 Parameterisation fault

The control's settings are wrong or incomplete for the boiler it is fitted to. Common after a control board swap or a part-finished commissioning. Call an engineer.

153 Appliance locked manually

The boiler has been deliberately locked out at the control, not stopped by a fault. Often left that way after servicing. Worth calling us before assuming something has broken.

105 Service display

Not a fault. The boiler is telling you a service interval has been reached. It will keep running, but book the service. See boiler servicing London.

127 Thermal disinfection temperature not reached

On systems with a hot water cylinder, the anti legionella cycle did not get the water hot enough. Worth attending to rather than ignoring. Call an engineer.

Sensors and add on modules

330 to 333 Sensor input BX1 to BX4 has no function

A sensor has been wired to a configurable input that has not been assigned a job, or the sensor has failed. A commissioning fault rather than a broken boiler. Call an engineer.

98 and 99 Fault at extension module 1 or 2

An add on module, typically controlling a mixed circuit or a cylinder, has a fault or has lost communication with the boiler. Call an engineer.

171 and 172 Contact fault H1 or H5

An external contact wired into the control has signalled a fault. What it means depends on what was wired to it at installation, so it needs someone who can read the commissioning settings. Call an engineer.

No code, no heating

If the display is blank or the boiler simply is not firing with no number shown, check the room thermostat, the programmer and its batteries, and the fused spur. If those are all right, call us.

Note: Geminox is a European brand and its controls have changed across the THR, THRi, THRs and Merite ranges, so the same number does not always mean the same thing on every unit. The codes above come from a Geminox installation and maintenance manual and cover the faults we are called to most. If your display shows a number that is not listed, do not match it against a code list for another make simply because the number looks familiar. Call us with the number and the model from the data badge and we will tell you what it means before anyone attends.

Not sure which fault you have?

Call with your model and the code on the display. We will tell you what is likely involved before anyone attends.

0203 868 6251

Most Searched Geminox Problems

If you are seeing a lockout, loss of hot water, or your Geminox boiler keeps resetting, tell us the fault code and model and we will confirm the safest next step.

133 – ignition lockout

Code 133 is the one you are most likely to see on a Geminox. The boiler attempted to light and no flame was proved. Common causes include a gas supply problem, a worn or sooted ionisation electrode, or a blocked condensate pipe in winter. Check gas is on elsewhere in the home. Reset once. If the lockout returns, stop and call an engineer.

323 – low pressure

If your Geminox shows 323, system pressure has dropped below the minimum operating level. Top up via the filling loop to around 1.0 to 1.5 bar when cold. If pressure drops again within days, there may be a leak in the system or a failing expansion vessel. Call an engineer to find the cause.

119 – overheat protection

If your Geminox shows 119, the heat exchanger limiter has tripped and the boiler has locked out for safety. This can indicate a circulation problem, pump failure, or a blocked heat exchanger. Do not keep resetting. Call an engineer to check the system.

No hot water but heating works

On Geminox combi boilers, you may get heating but no hot water, or the reverse. This often points to a diverter valve issue. The diverter valve directs hot water between taps and radiators. When it wears or sticks, hot water delivery becomes unreliable. Call an engineer for diagnosis.

Why Geminox Boilers Develop Faults

Geminox is a European manufacturer with a range of condensing boilers. Here is what we commonly see.

Ionisation electrode wear

The control proves the flame through an ionisation electrode, which is why codes 133 and 128 are the two we see most. When the electrode wears, sooths over or drifts out of position, the boiler cannot prove a flame and locks out. Condensate blockages in winter contribute to repeat lockouts too.

Low pressure and expansion vessel faults

Code 323 usually points to a failing expansion vessel or a weeping pressure relief valve. The expansion vessel absorbs pressure changes as water heats and cools. If the diaphragm fails or the air charge is lost, pressure drops can occur.

Circulation and pump issues

Codes 119 and 130 both point at heat not getting away from the boiler quickly enough. This may be caused by a failing pump, sludge buildup, or closed radiator valves. A powerflush may help restore flow.

Commissioning and configuration faults

Geminox runs a configurable Siemens control, which is a strength when it is set up properly and a nuisance when it is not. Codes 152 and the 330 series are settings faults rather than broken parts, and they often show up after a board change or an unfinished commissioning.

Diverter valve on combi boilers

The diverter valve directs hot water between your taps and radiators. When it wears or sticks, you may get heating but no hot water, or the reverse.

Geminox Models We Repair

We repair Geminox combi, system, and regular boilers in London, including:

Geminox boiler repairs London We repair every Geminox model Combi, system and regular boilers, current ranges and older units
THRi range THRi condensing boilers
THRs range THRs condensing models
Megalisthe range Megalisthe condensing models
Merite range Merite ZEM and related units
Condensing range Various Geminox condensing units
Other models Older Geminox boilers

Geminox parts can be more specialist than mainstream UK brands. We check availability before attending and advise honestly if repair is not viable or cost effective.

Repair or Replace Your Geminox Boiler?

We help you decide based on age, reliability, and parts availability.

Repair makes sense when

  • Boiler is under 10 years old
  • This is the first major fault
  • Parts are readily available
  • Boiler has been regularly serviced

Replacement may be better when

  • Boiler is 12 to 15 years old or more
  • You have had multiple breakdowns recently
  • Parts are obsolete or hard to source
  • The boiler is undersized for the property
  • Energy bills are higher than expected for the property size

Our engineers give honest assessments. We focus on safety and reliability, not pushing unnecessary replacements.

Geminox Boiler Servicing

Annual servicing reduces breakdown risk and keeps your Geminox boiler running efficiently. See Boiler servicing London.

Landlords and Letting Agents

We provide boiler repairs and gas safety certification for landlords across London. See Landlord gas safety certificate (CP12).

London based boiler repair engineers

Geminox Repairs Across London

London wide coverage for Geminox boiler repairs. Book an engineer or view our London areas we cover.

Have your postcode and fault code ready and we will confirm the quickest appointment slot.

Geminox Boiler Repair FAQs

How quickly can you attend for a Geminox breakdown?

We offer same day attendance where slots are available. For no heating or hot water, we prioritise urgent breakdowns. Call our 24/7 line and we will advise availability.

Why does my Geminox show a number instead of a letter code?

Geminox uses a Siemens burner management control, which reports faults as numbers rather than the two letter codes most British brands display. A Geminox showing 133 is telling you it could not prove a flame. There is nothing wrong with the display.

Do you carry Geminox parts?

Geminox parts can be more specialist than mainstream UK brands. We check availability and source parts as quickly as possible. For common faults, we often have compatible components available.

Is it safe to reset my Geminox boiler?

Try one reset. If the fault returns after resetting, stop and call an engineer. Do not keep resetting, especially for 119 and 110 where a safety limiter has tripped.

What customers say

Verified Google reviews. 4.6 out of 5.

★★★★★

Engineer very helpful and time efficient

Fiona GaylorGoogle review
★★★★★

Excellent from start to finish. The Engineer was helpful on the phone diagnosing the issue, and was able to start and finish the work in good time, and made every effort to do the best job possible. All working well, and was able to get a long guarantee.

GeorgeGoogle review
★★★★★

Fix the boiler same day great job life saver

B M Sidratul MuntahaGoogle review

Speak to Our Team

For safe next steps, call now.

Call 0203 868 6251

Book an Engineer ›

Gas Safe registered · 24/7 call handling · Quote before work
24 Hour Boiler Repairs, 86-90 Paul Street, London EC2A 4NE


Trusted 24 hour boiler repairs - call 0203 868 6251

Specialist for all boilers including:


Google reviews

★★★★★4.6/5 on Google
★★★★★

Used this company after being recommended and I’m glad I did. The engineer was punctual, honest about costs and carried out the work to a very high standard. Felt like a trustworthy service.

Siva YelakarajulaGoogle review
★★★★★

Good value for money & was able to sort out my boiler quickly by ordering next day delivery for broken parts. Friendly, punctual service and laid out all the costs beforehand which was helpful. Would recommend.

Emma CourtneyGoogle review
★★★★★

Booked them in for a power flush after ongoing heating issues. The engineer was very thorough and explained what was being done at each stage. We noticed a huge difference in how quickly the radiators now heat up.

S ThanuGoogle review


Find prices & book repair online ●
Call now Find prices